Skip to main content

About load , types and uses


LOADS

Structural loads or actions are forces, deformations, or accelerations applied to a structure or its components. Loads cause stresses, deformations, and displacements in structures. ... Engineers often evaluate structural loads based upon published regulations, contracts, or specifications.

LOAD TYPES

The determination of the loads acting on a structure is a complex problem. The nature of the loads varies essentially with the architectural design, the materials, and the location of the structure. Loading conditions on the same structure may change from time to time, or may change rapidly with time.


  • Loads are usually classified into two broad groups: dead loads and live loads. Dead loads (DL) are essentially constant during the life of the structure and normally consist of the weight of the structural elements. On the other hand, live loads (LL) usually vary greatly. The weight of occupants, snow and vehicles, and the forces induced by wind or earthquakes are examples of live loads. The magnitudes of these loads are not known with great accuracy and the design values must depend on the intended use of the structure.

In structural analysis three kinds of loads are generally used:

  • Concentrated loads that are single forces acting over a relatively small area, for example vehicle wheel loads, column loads, or the force exerted by a beam on another perpendicular beam.
  • Line loads that act along a line, for example the weight of a partition resting on a floor, calculated in units of force per unit length.
  • Distributed (or surface) loads that act over a surface area. Most loads are distributed or are treated as such, for example wind or soil pressure, and the weight of floors and roofing materials.


Dead Loads (DL)

The structure first of all carries the dead load, which includes its own weight, the weight of any permanent non-structural partitions, built-in cupboards, floor surfacing materials and other finishes. It can be worked out precisely from the known weights of the materials and the dimensions on the working drawings. Although the dead load can be accurately determined, it is wise to make a conservative estimate to allow for changes in occupancy; for example, the next owner might wish to demolish some of the fixed partitions and erect others elsewhere.

Live Loads (LL)

All the movable objects in a building such as people, desks, cupboards and filing cabinets produce an imposed load on the structure. This loading may come and go with the result that its intensity will vary considerably. At one moment a room may be empty, yet at another packed with people. Imagine the `extra' live load at a lively party!

Wind Load (WL)

Wind has become a very important load in recent years due to the extensive use of lighter materials and more efficient building techniques. A building built with heavy masonry, timber tiled roof may not be affected by the wind load, but on the other hand the structural design of a modern light gauge steel framed building is dominated by the wind load, which will affect its strength, stability and serviceability. The wind acts both on the main structure and on the individual cladding units. The structure has to be braced to resist the horizontal load and anchored to the ground to prevent the whole building from being blown away, if the dead weight of the building is not sufficient to hold it down. The cladding has to be securely fixed to prevent the wind from ripping it away from the structure.

Snow Load (SL)

The magnitude of the snow load will depend upon the latitude and altitude of the site. In the lower latitudes no snow would be expected while in the high latitudes snow could last for six months or more. In such locations buildings have to be designed to withstand the appropriate amount of snow. The shape of the roof also plays an important part in the magnitude of the snow load. The steeper the pitch, the smaller the load. The snow falling on a flat roof will continue to build up and the load will continue to increase, but on a pitched roof a point is reached when the snow will slide off.

Earthquake Load

Earthquake loads affect the design of structures in areas of great seismic activity, such as north and south American west coast, New Zealand, Japan, and several Mediterran

Comments

Popular posts from this blog

Hardy slab and where it use

  HARDY SLAB :- These kind of slabs are generally seen in Dubai and China. This  slab is constructed by hardy Bricks. Hardy bricks are hollow bricks and made up of concrete Hollow blocks are used to fill portions of the slab thickness it saves the  amount of concrete and hence the own weight of the slab is reduced. This kind of slab has a more thickness when compared with the conventional one. The thickness of hardy slab is 0.27m. The method of installing Hardy slab is different from normal  and it is clearly explained below: This is a one of the types of concrete slabs. The dimensions of Hardy brick is 40cm x 20cm x 20cm The process of execution is as follows: Step 1   : Formwork is arranged and then shutters are fixed on the formwork. Step 2  : Hardy blocks are placed on the shutter with one brick gap on the entire shutter. Step 3  : The gaps between the bricks are called as rib. Reinforcement is provided in a form of beam within the ...

About slump cone test in concrete

Concrete Slump Test for Workability -Procedure and Results. Concrete slump test is to determine the workability or consistency of concrete mix prepared at the laboratory or the construction site during the progress of the work. Procedure for Concrete Slump Test: Clean the internal surface of the mould and apply oil. Place the mould on a smooth horizontal non- porous base plate. Fill the mould with the prepared concrete mix in 4 approximately equal layers. Tamp each layer with 25 strokes of the rounded end of the tamping rod in a uniform manner over the cross section of the mould. For the subsequent layers, the tamping should penetrate into the underlying layer. Remove the excess concrete and level the surface with a trowel. Clean away the mortar or water leaked out between the mould and the base plate. Raise the mould from the concrete immediately and slowly in vertical direction. Measure the slump as the difference between the height of the mould and that of height poin...

Waffle slab and where to use

  WAFFLE SLAB :- Waffle slab is a reinforced concrete roof or floor containing square grids with deep sides. This kind of slab is majorly used at entrance of hotels, Malls, Restaurants for good pictorial view and to install artificial lighting. This a  type of slab where we find hollow hole in the slab when the formwork is removed.  Firstly PVC trays (pods) are placed on shuttering then reinforcement is provided between the pods and steel mesh is provided at top of the pods and then concrete is filled. After concrete sets the formwork is removed and PVC pods are not removed. This forms hollow hole in it in which hole is closed at one end. The concrete waffle slab is often used for industrial and commercial buildings while wood and metal waffle slabs are used in many other construction sites. This is a one of the types of concrete slabs. Where to use? A waffle slab is a type of slab with holes underneath, giving an appearance of waffles. It is usually used where lar...